ACC Plus is a powerful cleaning agent for cleaning of diesel
engine air coolers, scavenging air systems and the compressor
side of turbochargers. ACC Plus is a microemulsion type cleaner,
where a synergistic blend of biodegradable surfactants and low
toxicity solvents replace the use of the harmful solvents
traditionally used in air cooler cleaners without reducing the
cleaning performance. It is formulated to meet the latest
environmental standards, and is non toxic both to the environment
and to persons handling it. ACC Plus contains no chlorinated or
aromatic hydrocarbon solvents, nonylphenol ethoxylates or other
substances harmful to the environment.
Features
• Meets the latest environmental standards
• Equal cleaning performance to traditional cleaners based
on harmful chlorinated solvents
• Low toxicity, low evaporation and pleasant smell
• Formulated to remove oil, grease and carbon deposits from
air coolers and scavenging systems
• Maintains, stabilises and maximises air cooler efficiency
• Leaves no residue and has no harmful effect on engine.
• Can be used for handspray cleaning while diesel engine is
stationary
• Ideal for use in soak bath or cleaning tanks, such as the
Chemical Cleaning Unit and the Ultrasonic
Benefits
• Efficient and economical
Ordering information
Product number Product name
698704 ACC PLUS 25 LTR
Directions for use
Recirculation method in-situ
For this cleaning procedure the engine needs to be stopped and secured. Permanently installed spray nozzles in
combination with a cleaning solution tank and pump, such as the Unitor Chemical Cleaning Unit should be used. It is
advised to blind off the cooler outlet. Properly mix water and 10-30% ACC Plus, depending on the severity of the
contamination, in the tank. Connect the pump's outlet to the nozzle assembly and the air cooler drain to the tank.
Start the pump and spray the solution through the nozzles over the entire surface of the cooler and drain back to the
tank. Circulate the solution for a period of 1 to 6 hours. After cleaning, rinse with fresh water. Remove the outlet blind
and disconnect the pump and tank loop.
Soaking method in-situ
For this cleaning procedure the engine needs to be stopped and secured. Blind off the cooler outlet and flood the
cooler with a solution of 10-30% ACC Plus in water depending on the severity of the contamination. Soak for a
period of 1 to 6 hours and drain to slop tank. Agitation by means of steam or compressed air will improve the
cleaning effect. After cleaning, rinse with fresh water. Remove outlet blind and close drain.
Out of Service Cleaning:
Soak bath method
Remove the cooler from the engine and place in a soak bath filled with a solution of 10-30% ACC Plus in water for a
period of 1-6 hours. Agitation by means of steam or compressed air will improve the cleaning effect. After cleaning
rinse with fresh water and reinstall the cooler. This method is also suitable for machine parts with stubborn carbon
deposits.
Hand spray method
For this cleaning procedure the engine needs to be stopped and secured. Open the inspection cover on top of the
cooler and the drain valve. Spray undiluted ACC Plus into the tube nest, with e.g. a Unitor Jet Spray Unit, and allow
to penetrate into the deposits for a minimum of 1 hour. Rinse thoroughly with a high pressure jet such as a Unitor
High Pressure Machine. Close inspection cover and drain.
In-service cleaning
The general principle is to inject a solution of ACC Plus into the air trunking upstream of the charge air cooler
followed by a clean water rinse. For efficient cleaning of air coolers, it is necessary to use correctly installed dosing
and injection equipment. To calculate the amount of solution required to clean an air cooler, calculate or find the
cross-sectional area of the cooler and use 3 litres of cleaning solution per square metre or as table below:
Engine HP Solution mix. with 25% ACC Plus
6,000 to 12,000 3 litre mix
12,000 to 24,000 4.5 litre mix
24,000 or more 6 litre mix
For in-service cleaning of air coolers and the air-side of turbochargers, a solution of 25% ACC Plus in freshwater is
recommended.
The appropriate dosage of cleaner is then placed in the dosing pot and injected up stream of the air cooler for a
period of 10 minutes. After a further 10 minutes, a similar quantity of fresh water is injected to rinse off the emulsified
deposits. Rate and frequency of application depends mainly on the condition of the air coolers. However when
starting with the use of ACC Plus, recommended injection is every 24 hours. After the initial cleaning period, the
cleaning effect should last for 48 hours of operational time. Although frequency of cleaning may vary, the calculated
cleaning dose should remain the same. This cleaning method is only recommended if approved by the engine
manufacturer!
Documentation